Revision as of 16:55, 1 June 2018

The TS-7180 provides three standard RS-232 COM ports, and one RS-485 COM port. The latter has auto-transmit-enable. All of these ports are presented on the P5 connector. The RS-485 port has an on-board terminator that may be enabled by installing the "485" jumper.

UART TX RX
ttymxc1 P5-5 P5-6
ttymxc4 P5-2 P5-3
ttymxc6 P5-7 P5-8


UART 485+ 485-
ttymxc3 P5-13 P5-14
Note: The RS-232 transceiver chip on the board must be enabled before the COM ports can be used. This is done by running the command "tshwctl -a 21 -w 3"