TS-8100 COM: Difference between revisions
From embeddedTS Manuals
No edit summary |
No edit summary |
||
Line 72: | Line 72: | ||
|- | |- | ||
| 4 | | 4 | ||
| [[#UARTs|XUART6 RS422+]] <ref name=rs422>This is an RS485 port with RX only</ref> | | [[#UARTs|XUART6 RS422+]] <ref name=rs422>This is an RS485 port with RX only</ref> <ref name=opcan485 /> | ||
|- | |- | ||
| 5 | | 5 | ||
Line 87: | Line 87: | ||
|- | |- | ||
| 9 | | 9 | ||
| [[#UARTs|XUART6 RS422-]] <ref name=rs422 /> | | [[#UARTs|XUART6 RS422-]] <ref name=rs422 /> <ref name=opcan485 /> | ||
|} | |} | ||
Latest revision as of 12:55, 3 December 2013
The TS-8100 includes 3 2x5 0.1" pitch COM headers that feature RS232, RS485, and CAN ports. These follow a different pin layout which corresponds with a standard 10 pin header standard for UARTs. The RC-DB9 is available to convert these ports to a DB9.
Pinout | Header | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||
| ||||||||||||||||||||||||
|
- ↑ This header is brought out to both a 2x10 header and a #DB9.
- ↑ CONSOLE RS232 RXD with "Console Enable" jumper on or XUART1 RS232 RXD with "Console Enable" jumper off
- ↑ CONSOLE RS232 TXD with "Console Enable" jumper on or XUART1 RS232 TRXD with "Console Enable" jumper off
- ↑ 4.0 4.1 The second RS485 transceiver requires OP-CAN2-485 to be ordered with the board
- ↑ 5.0 5.1 This is an RS485 port with RX only
- ↑ 6.0 6.1 6.2 6.3 The second CAN transceiver requires OP-CAN2-485 to be ordered with the board