Modbus Peripheral Baud: Difference between revisions

From embeddedTS Manuals
(Created page with "{|class=wikitable |- ! Value ! Baud Rate ! Maximum CAT5 Cable Length |- | 0 | 300 | 1200 meters |- | 1 | 600 | 1200 meters |- | 2 | 1200 | 1200 meters |- | 3 | 2400 | 1200 met...")
 
No edit summary
Line 1: Line 1:
{|class=wikitable
{|class=wikitable style="text-align: center"
|-
|-
! Value
! Value
! Baud Rate
! Communication Bit Rate
! Maximum CAT5 Cable Length
! Maximum CAT5 Cable Length
|-
|-
Line 46: Line 46:
|-
|-
| 10
| 10
| 230.4K
| 230.4K <ref name=mxuart> On Linux systems, stting these bit rates requires code using ioctl() with the TCGETS2 and TCSETS2 parameters.</ref>
| 400 meters
| 400 meters
|-
|-
| 11
| 11
| 460.8K
| 460.8K <ref name = mxuart />
| 200 meters
| 200 meters
|-
|-
| 12
| 12
| 1040K
| 1040K <ref name = mxuart />
| 100 meters
| 100 meters
|-
|-
| 13
| 13
| 2080K
| 2080K <ref name = mxuart />
| 50 meters
| 40 meters
|-
|-
| 14
| 14
| 4160K
| 4160K <ref name = mxuart />
| 25 meters
| 20 meters
|}
|}

Revision as of 15:03, 19 May 2014

Value Communication Bit Rate Maximum CAT5 Cable Length
0 300 1200 meters
1 600 1200 meters
2 1200 1200 meters
3 2400 1200 meters
4 4800 1200 meters
5 9600 1200 meters
6 19.2K 1200 meters
7 38.4K 1200 meters
8 57.6K 1200 meters
9 115.2K 800 meters
10 230.4K [1] 400 meters
11 460.8K [1] 200 meters
12 1040K [1] 100 meters
13 2080K [1] 40 meters
14 4160K [1] 20 meters
  1. 1.0 1.1 1.2 1.3 1.4 On Linux systems, stting these bit rates requires code using ioctl() with the TCGETS2 and TCSETS2 parameters.