The TS-7180 provides three standard RS-232 COM ports, and one RS-485 COM port. The latter has auto-transmit-enable. All of these ports are presented on the P5 connector. The RS-485 port has an on-board terminator that may be enabled by installing the "485" jumper.
UART | TX | RX |
---|---|---|
ttymxc1 | P5-5 | P5-6 |
ttymxc4 | P5-2 | P5-3 |
ttymxc6 | P5-7 | P5-8 |
UART | 485+ | 485- |
---|---|---|
ttymxc3 | P5-13 | P5-14 |