TS-7180 COM Ports

From embeddedTS Manuals
Revision as of 17:25, 24 July 2018 by Ian (talk | contribs)

The TS-7180 provides three standard RS-232 COM ports, and one RS-485 COM port. The latter has auto-transmit-enable. All of these ports are presented on the P5 connector. The RS-485 port has an on-board terminator that may be enabled by installing the "485" jumper.

UART TX RX
ttymxc1 P5-5 P5-6
ttymxc4 P5-2 P5-3
ttymxc6 P5-7 P5-8


UART 485+ 485-
ttymxc3 P5-13 P5-14
Note: The RS-232 transceiver chip on the board must be enabled before the COM ports can be used. This is done by running the command "tshwctl -a 21 -w 3"


If the second CAN option is not installed, a fourth RS-232 uart will be available on P5.

UART TX RX
ttymxc6 P5-10 P5-11


The HD1 header contains TTL-level TX/RX pins that may be used to connect to a CPU uart, with the caveat that to do so, one of the assigned uarts must be reassigned to the header. The reassignment is done by writing to the register at address 308 in the FPGA. The table in the FPGA Registers section shows which UARTS may be used.