Line 19: | Line 19: | ||
'''Description''': | '''Description''': | ||
The Cavium STR8100 integrated PHY in some circumstances can drop connection to the network. You can see this in dmesg as | The Cavium STR8100 integrated PHY in some circumstances can drop connection to the network. You can see this in dmesg as: | ||
star_nic_shutdown: stoping patch check. | star_nic_shutdown: stoping patch check. | ||
Revision as of 15:35, 31 October 2012
Synopsis | Link drop with certain cable lengths/switches on 100Mb/s networks |
Severity | Normal |
Class | Kernel Bug |
Affected | All TS-75XX/TS-4500 Boards |
Status | Workarounds available |
Description:
The Cavium STR8100 integrated PHY in some circumstances can drop connection to the network. You can see this in dmesg as:
star_nic_shutdown: stoping patch check.
The issue appears to correspond to the length of cable used as well as the network device connected to the board.
Workaround:
You can force the cavium PHY to 10MB/s which drastically improves reliability, and in most cases eliminates the issue.
# From the initrd:
devmem 0x70000004 32 0x43075
# From Debian
busybox devmem 0x70000004 32 0x43075
This will disable the link speed auto-negotiation and force the PHY to communicate at 10Mb/s. This only works in cases where the link is up all the time. If link is being connected/disconnected you would need to reset the interface (ifdown && ifup) and run the devmem command again.