TS-8100 COM: Difference between revisions

From embeddedTS Manuals
(Created page with "The TS-8100 includes 3 2x5 0.1" pitch COM headers that feature RS232, RS485, and CAN ports. {| ! Pinout ! Header |- | {| class="wikitable" |+ COM1 header <ref>This header i...")
 
No edit summary
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
The TS-8100 includes 3 2x5 0.1" pitch COM headers that feature RS232, RS485, and CAN ports.
The TS-8100 includes 3 2x5 0.1" pitch COM headers that feature RS232, RS485, and CAN ports.  These follow a different pin layout which corresponds with a standard 10 pin header standard for UARTs.  The [[RC-DB9]] is available to convert these ports to a DB9.


{|  
{|  
Line 17: Line 17:
|-
|-
| 2
| 2
| [[#UARTs|CONSOLE RS232 RXD]] with "Console Enable" jumper on
| RS232 RXD <ref>
or [[#UARTs|XUART1 RS232 RXD]] with "Console Enable" jumper off
[[#UARTs|CONSOLE RS232 RXD]] with "Console Enable" jumper on or [[#UARTs|XUART1 RS232 RXD]] with "Console Enable" jumper off </ref>
|-
|-
| 3
| 3
| [[#UARTs|CONSOLE RS232 TXD]] with "Console Enable" jumper on
| RS232 TXD
or [[#UARTs|XUART1 RS232 TRXD]] with "Console Enable" jumper off
<ref> [[#UARTs|CONSOLE RS232 TXD]] with "Console Enable" jumper on
or [[#UARTs|XUART1 RS232 TRXD]] with "Console Enable" jumper off </ref>
|-
|-
| 4
| 4
Line 62: Line 63:
|-
|-
| 1
| 1
| [[#UARTs|XUART4 RS485+]]
| [[#UARTs|XUART4 RS485+]] <ref name=op485> The second RS485 transceiver requires OP-CAN2-485 to be ordered with the board</ref>
|-
|-
| 2
| 2
| [[#UARTs|XUART0 RS485-]]
| [[#UARTs|XUART3 RS232 RXD]]
|-
|-
| 3
| 3
Line 71: Line 72:
|-
|-
| 4
| 4
| [[#UARTs|XUART6 RS422+]] <ref name=rs422>This is an RS485 port with RX only</ref>
| [[#UARTs|XUART6 RS422+]] <ref name=rs422>This is an RS485 port with RX only</ref> <ref name=opcan485 />
|-
|-
| 5
| 5
Line 77: Line 78:
|-
|-
| 6
| 6
| [[#UARTs|XUART4 RS485-]]
| [[#UARTs|XUART4 RS485-]] <ref name=op485 />
|-
|-
| 7
| 7
Line 86: Line 87:
|-
|-
| 9
| 9
| [[#UARTs|XUART6 RS422-]] <ref name=rs422 />
| [[#UARTs|XUART6 RS422-]] <ref name=rs422 /> <ref name=opcan485 />
|}
|}


Line 108: Line 109:
|-
|-
| 4
| 4
| [[#CAN|CAN2_H]]
| [[#CAN|CAN2_H]]<ref name=opcan485> The second CAN transceiver requires OP-CAN2-485 to be ordered with the board</ref>
|-
|-
| 5
| 5
Line 123: Line 124:
|-
|-
| 9
| 9
| [[#CAN|CAN2_L]]
| [[#CAN|CAN2_L]] <ref name=opcan485 />
|-
|-
| 10
| 10

Latest revision as of 12:55, 3 December 2013

The TS-8100 includes 3 2x5 0.1" pitch COM headers that feature RS232, RS485, and CAN ports. These follow a different pin layout which corresponds with a standard 10 pin header standard for UARTs. The RC-DB9 is available to convert these ports to a DB9.

Pinout Header
COM1 header [1]
Pin Name
1 XUART0 RS485+
2 RS232 RXD [2]
3 RS232 TXD

[3]

4 CAN_H
5 GND
6 XUART0 RS485-
7 XUART2 RS232 TXD
8 XUART2 RS232 RXD
9 CAN_L
10 Unused

TS-8100-COM.png

COM2 header
Pin Name
1 XUART4 RS485+ [4]
2 XUART3 RS232 RXD
3 XUART3 RS232 TXD
4 XUART6 RS422+ [5] [6]
5 GND
6 XUART4 RS485- [4]
7 Unused
8 Unused
9 XUART6 RS422- [5] [6]
COM3 header
Pin Name
1 Unused
2 XUART5 RS232 RXD
3 XUART5 RS232 TXD
4 CAN2_H[6]
5 GND
6 Unused
7 Unused
8 XUART5 RS232 CTS
9 CAN2_L [6]
10 Unused
  1. This header is brought out to both a 2x10 header and a #DB9.
  2. CONSOLE RS232 RXD with "Console Enable" jumper on or XUART1 RS232 RXD with "Console Enable" jumper off
  3. CONSOLE RS232 TXD with "Console Enable" jumper on or XUART1 RS232 TRXD with "Console Enable" jumper off
  4. 4.0 4.1 The second RS485 transceiver requires OP-CAN2-485 to be ordered with the board
  5. 5.0 5.1 This is an RS485 port with RX only
  6. 6.0 6.1 6.2 6.3 The second CAN transceiver requires OP-CAN2-485 to be ordered with the board