TS-7970 Terminal Blocks: Difference between revisions

From embeddedTS Manuals
No edit summary
No edit summary
Line 78: Line 78:
<References />
<References />


The DIO_1 and DIO_2 IO can be outputs, or inputs.  As inputs the digital threshold is 1.2V.  To guarantee low it must be < 0.5V, or for high > 2.0V.  There is an internal 1.5k pullup to 5V that will bias the input high.  As outputs these IO can sink up to 500mA.
The DIO_1 and DIO_2 IO can be outputs, or inputs.  As inputs the digital threshold is 1.2V.  To guarantee low it must be < 0.5V, or for high > 2.0V.  When the IO is low the external device needs to sink up to 3.5mA.  When the IO is high the external device needs to source 10 uA max.  There is an internal 1.5k pullup to 5V that will bias the input high.  As outputs these IO can sink up to 500mA.

Revision as of 16:06, 7 June 2016

The TS-7970 includes two removable terminal blocks (OSTTJ0811030) for power, UARTs, CAN, and other general purpose IO.

TS-7970 terminal block connectors.png


TS-7970 Terminal Blocks.png
P1-A
Pin # Description
1 Ground
2 STC_485+ (/dev/ttyMAX0)
3 STC_485- (/dev/ttyMAX0)
4 STC_CAN_2_H (can1 interface)
5 STC_CAN_2_L (can1 interface)
6 Power Input (8-28VDC)
7 Power Input (5VDC)
8 Ground [1]
P1-B
Pin # Description
1 Ground
2 AD_P10 (4-20mA analog input)
3 AD_P11 (4-20mA analog input)
4 AD_P12 (4-20mA analog input)
5 DIO_1 (30VDC IO)
6 DIO_2 (30VDC IO)
7 RS-232_STC_TXD (/dev/ttymxc4)
8 RS-232_STC_RXD (/dev/ttymxc4)
  1. This ground should be used for the power supply since it includes a ferrite bead to help suppress noise.

The DIO_1 and DIO_2 IO can be outputs, or inputs. As inputs the digital threshold is 1.2V. To guarantee low it must be < 0.5V, or for high > 2.0V. When the IO is low the external device needs to sink up to 3.5mA. When the IO is high the external device needs to source 10 uA max. There is an internal 1.5k pullup to 5V that will bias the input high. As outputs these IO can sink up to 500mA.